Plasma Lipidomic Fingerprinting to Distinguish among Hepatitis C-related Hepatocellular Carcinoma, Liver Cirrhosis, and Chronic Hepatitis C using MALDI-TOF Mass Spectrometry: a Pilot Study

Authors

  • Ana Maria Passos-Castilho Department of Medicine, Federal University of Sao Paulo, Sao Paulo, SP, Brazil
  • Edson Lo Turco Department of Surgery, Federal University of Sao Paulo, Sao Paulo, SP, Brazil
  • Maria Lúcia Ferraz Department of Gastroenterology, Federal University of Sao Paulo, Sao Paulo, SP, Brazil
  • Carla Matos Department of Gastroenterology, Federal University of Sao Paulo, Sao Paulo, SP, Brazil
  • Ivonete Silva Department of Gastroenterology, Federal University of Sao Paulo, Sao Paulo, SP, Brazil
  • Edison Parise Department of Gastroenterology, Federal University of Sao Paulo, Sao Paulo, SP, Brazil
  • Eduardo Pilau Chemistry Institute, University of Campinas, Campinas, SP ; Department of Chemistry, University of Maringa, Maringa, PR, Brazil
  • Fabio Gozzo Chemistry Institute, University of Campinas, Campinas, SP, Brazil
  • Celso Granato Department of Medicine, Federal University of Sao Paulo, Sao Paulo, SP, Brazil

DOI:

https://doi.org/10.15403/jgld.2014.1121.pas

Keywords:

hepatocellular carcinoma, hepatitis C, lipidomics, fingerprints, lipids, MALDI-MS

Abstract

Background & Aims: Hepatitis C (HC) is a major cause of hepatocellular carcinoma (HCC), and a late diagnosis is the main factor for the poor survival of patients. There is an urgent need for identifying sensitive and specific biomarkers for HCC diagnosis. In the present study, plasma lipid patterns of patients with HC-HCC, HC-liver cirrhosis (LC), and chronic HC (CHC) were assessed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS).

Methods. Plasma samples of 25 patients with HC-HCC, 15 patients with HC-LC, and 25 patients with CHC were evaluated by MALDI-MS using a Q-ToF premier (Synapt) mass spectrometer (Waters, Manchester, UK) equipped with a 200-Hz solid-state laser in the mass range between m/z (mass-to-charge ratio) of 700-1200.

Results. A total of 2205 ions were initially obtained and 7 ions (m/z) were highlighted as corresponding to the most important lipids to differentiate HCC patients from LC and CHC patients. The specific lipidomic expression signature generated resulted in an overall predictive accuracy of 93% of HC-HCC and HC-LC, and 100% of HC-HCC and CHC. The 7-peak algorithm distinguished HCC from LC with a sensitivity of 96% and a specificity of 87%, and HCC from CHC with both sensitivity and specificity of 100%.

Conclusion. MALDI-MS-specific signature peaks accurately distinguished patients with HC-HCC from those with HC-LC and CHC. The results indicate the potential of MALDI-MS and the selected peaks to improve HCC surveillance in patients with viral C cirrhosis and chronic hepatitis C.

Downloads

Published

2015-03-01

How to Cite

1.
Passos-Castilho AM, Lo Turco E, Ferraz ML, Matos C, Silva I, Parise E, Pilau E, Gozzo F, Granato C. Plasma Lipidomic Fingerprinting to Distinguish among Hepatitis C-related Hepatocellular Carcinoma, Liver Cirrhosis, and Chronic Hepatitis C using MALDI-TOF Mass Spectrometry: a Pilot Study. JGLD [Internet]. 2015 Mar. 1 [cited 2026 Jul. 15];24(1):43-9. Available from: https://www.jgld.ro/jgld/index.php/jgld/article/view/1243

Issue

Section

Original Article