Self-expandable Metal Stent Placement Combining Double Balloon Endoscopy with a Percutaneous Approach in a Roux-en-Y Hepaticojejunostomy

Authors

  • Jan J. Koornstra University Medical Center Groningen, Groningen, The Netherlands
  • Heyder Alkefaji University Medical Center Groningen, Groningen, The Netherlands

Keywords:

Double balloon enteroscopy, ERCP, stent, Roux-en-Y reconstruction

Abstract

The use of the double balloon endoscope for ERCP in patients with surgically altered anatomy has shown to be safe and feasible. This technique permits a variety of diagnostic and therapeutic possibilities. A case is presented of a 38-year old male, admitted with jaundice, 8 months after surgery for a malignant liver tumour with construction of a Roux-en-Y hepaticojejunostomy. A stenosis at the site of the biliodigestive anastomosis was diagnosed. Combining double balloon endoscopy with a percutaneous approach in a rendezvous procedure, it was possible to place a self-expandable biliary metal stent. This is the first report of a successful placement of a metallic stent using this technique.

Downloads

Published

2009-09-01

How to Cite

1.
Koornstra JJ, Alkefaji H. Self-expandable Metal Stent Placement Combining Double Balloon Endoscopy with a Percutaneous Approach in a Roux-en-Y Hepaticojejunostomy. JGLD [Internet]. 2009 Sep. 1 [cited 2026 Jul. 15];18(3):375-7. Available from: https://www.jgld.ro/jgld/index.php/jgld/article/view/2009.3.19

Issue

Section

Technique/Case report